Ruskin dampers. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. Ruskin dampers

 
Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies inRuskin dampers  Industrial Multi-Blade Control Damper

Greaves Rd. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Ruskin Literature. Marketing Literature; Case Studies;. Maximum velocity of 4,000 fpm. Find the pressure drop across a 18" wide x 18" (457 x 457) high Model CD80AF4 control damper. The TS150 must be installed at the factory and cannot be added in the field. Damper bearings shall be of UHMW and mechanically fastened by stainless steel set collars located out of the airstream. Such applications include isolation of air filtration systems or wherever hazardous duty airflow must be contained. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. Ruskin UL listed solutions are available. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for steel joist assemblies (L524). From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. Torque applied holding damper closed at 10 in. Rusin anuary 2021 Replaces Spec AIRFLOW-IQ-01 Pae 4 High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. Leading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. Butterfly blade. Ceiling Fire Dampers UL Classified Radiation Dampers Underwriters Laboratories has classified hundreds of specific Floor/Ceiling (F/Cs) and Roof/ Ceiling (R/Cs) and established Fire Resistance Ratings for each design ranging from 1/2 to 5 hours. G. Relief doors open automatically to prevent ductwork from imploding or exploding due to differential pressure. Learn more about the features, specifications and dimensions of the PVC12 damper from Ruskin, the leading manufacturer of air control. a. ©Ruskin October 2007 ® Spec FSD60-C-1007/Replaces FSD60/36-C-1206 APPLICATION The FSD60-C is two dampers in one. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. 7476 Fax: 816. 3 m/s) and 8” w. It features: Vertical blades. UL approval for dual directional airflow. AXLE All axles to extend 6" (152) beyond damper frame. 5. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. Ruskin offers blast suppression dampers which are custom designed to each application. for dampers up to 17. Ruskin CFD(R)2 and CFD(R)3 are UL Classified to provide protection to HVACRectangular Steel V-Groove. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowdamper that can be used as supply/return air plenum to connect to AHU unit below the ceiling assembly. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Models are designed for medium to high pressure applications and can be provided with manual control devices or factory installed electronic or pneumatic actuators. It features: Extruded aluminum construction. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. (1 kPa). The EFL closes and locks the damper when temperatures exceed 165°F (74°C)Ruskin FDR25SS is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Brand: Ruskin SKU: CDR92. be-csd-thailand@jci. Rev. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. a. 3 (damper installed with duct upstream and downstream). Specifier Select Option Dampers shall be equipped with factory installed damper position indication switch package. MODEL 914 SUGGESTED SPECIFICATION Suggested specification for Model 914 Ruskin Swartwout Fiber-glass Series round dampers (revision 6394). Ceiling dampers are to be factory installed in a 111/2" (292) tall R6 insulated ductboard box with a 1" (25) turned out flange and 1/2" (13)an AMCA registered laboratory. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. Static pressure and CFM are corrected to . Reinforcing plates are not required for assemblies consist-ing of two dampers attached end-to-end or three dampers attached side-to-side as depicted in figure 3. Higher velocities are not recommended for outside air openings, due to water penetration concerns. MODEL 912 SUGGESTED SPECIFICATION Suggested specification for Model 912 Ruskin Swartwout Fiberglass Series round dampers (revision 6394). 3 (damper installed with duct upstream and downstream). All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. Ruskin Literature. Dampers shall be Ruskin model FSDR25. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. The PSD – Positive Seal Damper – by Ruskin provides bubble tight leakage performance per AMCA Standard 500D for a wide range of applications where system shut-off and isolation is critical. Every damper is built with performance in mind and tested per AMCA standards. Access Doors. INSTALLATION For proper operation, damper must be installed square and free from racking. We are the leading manufacturer of air. R8039)<o:p></o:p> Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Curtain type. of damper with minimum of 20 in. lbs. Available with factory furnished sleeves. Pressure Relief Doors. Ruskin CD30AF1/CD30AF2 con-trol dampers. The pressure drop is the point at which the horizontal,. Use "Mount With Arrow Up" label as a guide for proper damper orientation. g. Ruskin’s Information is not a. , with order). Auto-Balancing. It is Leakage Class I classified and features: UL555S Class I. Damper shall be Ruskin model CDRS82. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Learn more about the features and. Dampers shall be Ruskin Swartwout Series Model CBDR912. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. The operable blades are opened and closed manually, or with the use of an actuator. The maximum opening. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. per sq. Dynamic fire dampers shall be Ruskin multiple model DFD60. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Dampers shall be in all respects equivalent to Ruskin model CBD2. g. g. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . The CFD8 is UL555C Classified Ceiling Fire (Radiation) Damper (CABS. The Ruskin backdraft damper model CBDR92 is designed to prevent backflow in high velocity HVAC and industrial process systems. The commercial dampers provide low pressure openings with exceptional pressure drop performance, while the industrial line includes heavier gauge materials to. Ruskin Literature. e. primary fire dampers DO NOT provide the necessary protection. Noise Control. Johnson Controls offers a broad range of HVAC dampers and louvers engineered to fit your unique application and size requirements. Dampers shall be in all respects equivalent to Ruskin model IL35. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. dampers. Dampers can be constructed of galvanized, stainless, or. Ruskin® Labor Saversfor fire and fire/smoke dampers include factory sleeves, PFMA mounting angles, and tagging by floor or by area. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. g. Each has added features that enable them to meet all high temperature, high pressure. The CD51 is structurally designed for velocities to 2000 fpm. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Haldeman is a stocking Manufacturer Representative and Distributor of HVAC products since 1933. 5 hr. FILES (0) Share this page: Ruskin's Automatic Balancing Dampers provide a reliable way to maintain constant airflow volume and occupant comfort in high-rise buildings. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. As a Corridor Damper it is designed to be used in openings in the ceilings ofRuskin anuary 2021 Page 2 1. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Do not weld or fasten angles together at cor-ners of dampers. The CFD7T is UL555C Classified Ceiling Fire Damper for wood construction. Damper size shall not exceed 90" x 48" (2286 x 1219) or 48" x 90" (1219 x 2286). Dimensions shown in parentheses ( ) indicate millimeters. Following system stabilization, normal counter-balance operation will continue. Damper shall be in all respects equivalent to Ruskin BD6. lbs. The most effective method of energy-saving insulation. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. Issue ‘E’ Fuse Link 4. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. The results show that Ruskin’s CBS8BL dramatically reduces the blast impulse thus protec Ruskin blast damper charts below highlight results of independent third party lab testing of model CBS8BL to peak reflective pre B Impl ( ows ra m Ope nDu ct) Blast Impulse (Downstream Damper)of damper with minimum of 20 in. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. The PVC12 damper is a corrosion-resistant and low-maintenance device that can regulate air flow in ducts or pipes. 24VAC modulating actuators (spring return or fail-in-place) can. g. Learn about their history, products, news and experts on their website. Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowDamper is designed to operate with blades running horizontally and m ust be installed with center line of damper blades within the wall or floor when they are in the closed position. It features: Low leakage. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. Standard features vary by model to make application selection straightforward. Greaves Rd ansas City, O 600 P: 16 761-776 F 16 765-55 E ruskinruskin. FSD35. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Life Safety Products; Louver and Architectural; Louver Paint Finishes - Color Guide; Diffusers; Energy Recovery Ventilators; Commercial Control DampersRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD60FA is a combination fire/smoke damper that allows through the grille access to the damper, actuator and heat actuated device. Galvanized Steel V-Groove Blades. 3. damper actuators are UL listed for smoke control dampers or for combination fire/smoke rated dampers. and a maximum of 3 CFM sq. It features: For use in static systems Galvanized steel construction. ©Ruskin 2000 3900 Dr. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. The damper is rated for maximum velocity of 2,000 fpm (10. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. 5 21w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. lbs. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. g. Dampers above 18" (457) – 10 gage steel (3. The EFL is STANDARD on all fire/smoke dampers ordered with electric actuators. A. 2. The DTS gives maintenance personnel the ability to “cycle test” the fire/smoke damper by pushing and holding the button until the damper has cycled. Example: Maximum design total pressure of 8. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. The CD40 Series has 6" wide V-grooveThe PFL is a UL Classified heat responsive device used in conjunction with Ruskin fire/smoke dampers. Learn more about the FSD60 and its installation instructions from this document. 5. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Refer to the UL approved installation instructions for specific requirements. Windstops all around. These louvers are popular for warehouse applications and other structures in which you want to close the airflow without the use of a damper. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. 5" w. Ceiling Fire Dampers UL Classified Radiation Dampers for Wood Joist Construction The CFD7 is a UL Classified Ceiling Fire Damper that is UL approved for installation in ceilings constructed from wood joists. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. Greaves Rd. Ruskin fire/smoke dampers. 2. Ruskin Literature. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. Maximum 8" static pressure. A 1" (25) diameter jackshaft is normally used for. This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. A. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. While is it true that triple V blade dampers and modified single skin type have been qual-ified to 3000 - 4000 fpm or more at 4" w. g. Commercial Dampers. 00. Greaves Rd. The CD80AF2 Industrial Control damper has an 8" frame. g. Ruskin Company certifies that the SD50 shown hereon is licensed to bear the AMCA Seal. Welcome to Ruskin Rooftop Systems 972. Spec CBD4-507/Replaces CBD4-92000 ©Ruskin 2007 *Unit furnished approx 1/4" (6). Frame shall be 16 ga. Ruskin. Ruskin was founded in the Ruskin Heights area of Kansas City in 1958. The TDP05K is capable of measuring a velocity range from Oto 5,000 FPM and displaying the flow and temperature. See “Smoke Damper Multiple Section Detail” spec sheet for details. 3. Life Safety » Combination Fire/Smoke Dampers 1. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Their line includes duct smoke detectors, flanged breakaway connections, fire damper angles, auxiliary switches, and more. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Greaves Rd. Spec AIRFLOW-IQ-0121 STATD SPTS R ST T TT T R T. The CFDR2 is a UL555C Classified Round Ceiling Fire Damper. The CD51 Control Damper has a 5" frame. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. Dynamic fire dampers shall be Ruskin multiple model DFD35. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. g. • Operation Test The damper/actuator assembly is exposed to heated (250ºF or 350ºF) airflow (minimum 2,400 fpm and 4. Damper Maximum Size Velocity (FPM) Pressure (in. ©Ruskin 2002 FRAME QTY. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. Product offerings include Air Control & Distribution products,. 5. (2 kPa). and greater Carbon steel construction Butterfly bladeThe CFD7T-ST-BT is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. It features a galvanized steel frame, single skin blades, and a variety of actuator options. • For proper operation, damper must be installed square and free from. Ruskin ® 00 Dr. Standard, 1 1/2 and 3 hr. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Equipped with linkage out of the airstream. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. Industrial Multi-Blade Control Damper. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. g. Standard damper assemblies are furnished ¼” smaller. Swartwout series model 914 Heavy Duty Fiberglass Round Control Damper • Accurate control of airflow through the round duct • Designed specifically for corrosive environments • Premium constructed Vinyl Ester, Flange Mounted, single piece blade has 3 frame styles • Designed to withstand pressures up to 30" wg Differential PressureRuskin's premier damper for medium pressure commercial and industrial HVAC systems offers the lowest leakage available with a standard, commercial built damper. 761. Dampers Corridor Dampers Fire Dampers Smoke Dampers Ruskin® 3900 Dr. (Consult Ruskin for detailed CSI MasterFormat Specification. per sq. UL 555/555S 1. Mounting Angle FastenersCurtain Type Static Fire Dampers 3 Hour Ul555 Rated For Use In Static Systems Ruskin Model IBD23 is a 3 hour UL classified static (fans off) curtain style fire damper for use in HVAC systems that shut down during a fire event. Ruskin round and oval solutions are perfect for applications utilizing spiral duct, or transitioning from rectangular to round. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. Specifier Select Option Dampers shall be equipped with factory installed damper. Control dampers shall be produced in an ISO9001 certified factory. Airfoil blades, which. The AiQ-TD-50 offers accurate airflow measurement and control through electronicthermal dispersion technology utilized in Ruskin model TDP05K Airflow & Temperature Measuring probes(s) with the inclusion of Ruskin model CD50 control damper factory configured as one compact assembly. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. /Class III, V-Groove Blade,. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. > Case Studies. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. The CD82HT Industrial Control Damper has an 8" frame. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. Damper shall be Ruskin model PVC12. specification but their recommendedThe ZMD60 Zone Mixing Damper is suitable for multiple zone applications where high performance is required. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Damper locks together without bolts, screws, or. Enter the Pressure Drop Chart at the determined area factor. The majority of designs are rated at 2 or 3 hours. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. Dampers shall be in all respects equivalent to Ruskin model CBD6. the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). 2) wall thickness with 12 gage (2. Pressure Relief Doors. Maximum rating of 4,000 fpm and 4" w. lbs. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Airfoil blades, which have greater strength, less static pressure, superior sealing. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Page 1 INSTALLATION SUPPLEMENTS Horizontal Installation – 90"w x 91"h (2286 x 2311) or 114"w x 38"h. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. 3. Consult Ruskin or your Ruskin representative when damper is to be. 5hr Static Fire Dampers » 3hr Static. It features: 750 degree F standard temperature rating! A variety of applications in air and material volume control systems. Sun Control Sunshades. Built from strong materials and designed on state-of-the-art. It features: Airfoil blades, which have greater strength, produce less sound, greater sealing ability, and static pressure loss. Product• Ruskin FAST Angles • One piece angle shipped with the damper • Available in 1-½" or 2-½" • Metal, wood and masonry walls/floors • Permits damper installation before or after drywall installation • Approved for all Ruskin fire, smoke and fire/smoke dampers LaBOr Saver #2 IntegraL and factOry SLeeveSRuskin® has the largest selections of AMCA certified dampers in the industry. Damper shall be equivalent to Ruskin model ARD25. Life Safety Dampers. From light duty commercial applications to heavy duty industrial and process applications, Ruskin's comprehensive product portfolio includes high performance quality for every application. 2. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. The CD60GS is designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment orsurrounding space. The webpage also includes diagrams, dimensions, and performance data of the dampers, as well as installation and maintenance instructions. 248 Kpa) tested per AMCA 500. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below on dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Rectangular Silencers. Damper frames Dampers shall be constructed with premium vinyl ester resins suitable for specified. 761. com . Ceiling fire dampers, also known as "Radiation" dampers, are designed and tested to limit the radiant heat transfer through an air inlet/outlet opening in the ceiling membrane of a fire resistance rated floor/ceiling or. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. Constructed with durable galvanized steel. Dampers shall be designed for maximum 1500 fpm spot velocities and up to 4" w. Ruskin® 3900 Dr. Kansas City, MO 64030Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. Masonry Wall or Floor: #10 s elf-tapping concrete screws Wood/Steel Stud Wall: #10 screws. (25) sp. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. They are designed to be installed inside duct work rather than flange mounted. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. After 15 minutes, the damper is closed and reopened. Air control dampers (6 pages) Fire and Smoke Dampers Ruskin TS150 Operation Instructions (2 pages) Summary of Contents for Ruskin DIBD2. Greaves Rd. 3 sq. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Get a Quote. The ARD25 is. Furnish and install, at locations shown on plans or in accordance with schedules, counterbalance backdraft dampers that meet the following minimum construction standards: frame shall be (specify). 1. Ruskin Model ZCDR25 can be installed into existing round ductwork. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. Unlike conventional mounting angles that cannot be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: One piece angles (fastened together in the corners). b. Stainless Steel V-Groove Blades. V Groove & Single Blades. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. TION 1. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. max Extremely tight shut-off. Ruskin Fire/Smoke Dampers. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. CFDR7T - 2"x4" Truss Assemblies (Ref. Noise Control. Stainless Steel Construction See model (D)IBD2SS. 025" thick formed aluminum with concealed blade linkage, synthetic bearings and non. Built from. The standard finishes described herein represent those finishes usually selected, specified, or required for most. Availability: Get a Quote. Wood/Steel Stud Wall: #10 screws b. Email. Dampers above 40" (1016) – 10 gage with retainer ring. cheng@jci. The DIBD2/OW can be installed on either side of the wall or top or bottom side of the floor. g. g. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. Dampers may tolerate higher pressures and velocities than those listed here. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off.